High-Density and Liquid-Cooled AI Data Centers
High-density space with direct-to-chip liquid cooling, up to 130 kW per rack, built for GPU clusters and AI workloads.
- Per rack
- Up to 130 kW
- Cooling
- DLC · RDHx
- Floor load
- 2,000 kg/m²
- Network
- 800G-ready
High Density & AI: what's included
Every feature is delivered to the same standard in all 34 locations, under a single contract.
Direct-to-chip cooling
Liquid cooling to CPUs and GPUs through CDU and manifold infrastructure.
Rear-door heat exchangers
Supplements air cooling for racks in the 30–50 kW range.
Reinforced floors
Floors rated for 2,000 kg/m² to carry heavy GPU servers.
InfiniBand-ready
Rail-optimized cabling and low-latency cluster network design.
Leak detection
Continuously monitored leak sensors under every manifold and rack.
Heat reuse
Waste heat transferred to district heating networks.
The right configuration for your needs.
Pricing depends on capacity, location and contract term. Our solution architects prepare a quote within one business day.
High density
Air plus rear-door cooling
- 30 kW per rack
- Rear-door heat exchanger
- Hot-aisle containment
- 100G connectivity
Liquid cooling
Direct-to-chip
- 80 kW per rack
- CDU and manifolds
- Leak detection
- 400G connectivity
AI pod
Ready-made block for GPU clusters
- 130 kW per rack
- 8–32 rack blocks
- InfiniBand fabric
- 800G-ready
AI factory
Megawatt-scale AI hall
- Up to 5 MW
- Dedicated cooling loop
- Dedicated substation
- Phased delivery
High Density & AI in 34 locations.
Pick the facility closest to your users, or run the same configuration across multiple locations.
Latency calculatorFrequently used together.
Colocation
Host your own server and network hardware in Tier IV halls protected by 2N redundant power, precision cooling and seven layers of physical security.
ExplorePrivate Cages & Suites
Full physical isolation with your own access control, your own cameras and dedicated power circuits. From a 20 m² cage to a megawatt-scale private hall.
ExploreHigh Density & AI, explained.
For questions about your project, our solution architects reply within one business day.
Ask a questionWhich GPU systems do you support?
We design power, cooling and cabling for all high-draw GPU servers, including current-generation HGX and DGX systems.
Can we bring our own CDU for liquid cooling?
Yes. You can connect your own CDU to the facility water loop or use the CDU infrastructure we provide.
How quickly is an AI pod delivered?
Standard AI pod blocks are typically delivered within 8 to 12 weeks.